Installation

Questions about installing and configuring a Fluksometer.

Pulse Width / Gap and Ratio

following on from this thread end of page 1

https://www.flukso.net/content/pulse-output-100impkwh

I ended up with a 5000 pulse/kwh setting and pulse width of 30ms

That has worked fine for me until now.

I have an electric vehicle and also get free power between 11:00-14:00 so can consume over 25kwh

im not 100% sure how to work out the max kWh based on the pulse rate, pulse width and the pulse gap

Based on a pulse rate of 5000
pulse width of 30ms
I get a max of 12kwh? using a formula I created with data below
but its more like I get to about 20kwh before my readings start playing up (guessing im getting overlap) and its reads as no power.

I have set the pulse width to 20ms so I should get a little more before I get overlap and the formula gets it to 18kwh...
also not sure how the pulse gap and duty cycle fits into this?

I will drop my pulse rate of 5000 down if I have to but trying to work out my formula and make sure its correct and how I can somehow get 20kwh from what I have worked out to be 12kwh.
..

 "1 pulse per Wh (1000imp/kWh) => @30ms (50% duty cycle, so also gap at least 30ms - the "window" in which the next pulse may occur) you can detect 1/.06 = 16,67 Wh/sec equiv to 60 kWh (which should be sufficient ;-)) - with 150ms it would be "just" 1/.3 = 3,3 Wh/sec equiv to 12 kWh (which still should be sufficient); calculate for your actual pulses per unit - so with 150 ms you should be more than fine :-)"

Exchanged a FLM003E from my son. Replacing a broken FLM02E. Works fine. However.

I need a new userid with the same email adress. Server naming proc is refusing it.
Locally 192.168.255.1 and root /root I could get into local flukso and adapted the
necessary. Is there another way?Led 0 1 11 1 1 is ethernet without wifi and is OK. §Wifi WAN LAN Eth Beat power
But due to this change I got now Led 0 1 1 0 1 1. Lost ethernet and wifi.

Now all LED's are burning, except Wifi. I toggled 2-5 seconds to get Wifi in, but this doesn't work well. I also lost ethernet and get stuck with a login.
What should I do now to recover ?
Toggle 2-5 again?
fI need wiifi to access the flukso server.
???
Marc

no heartbeat FLM 2

Hi, My Flukso have no more heartbeat after power outage and internet outage. Following older topic https://www.flukso.net/content/no-ip-connect , i want to de-brick my Flukso.
I 'am using Ubuntu version 18.04 but dit not arrive at the last step:
$ wget http://www.flukso.net/files/flm02/tools/ap51-flash ==OK
$ wget http://www.flukso.net/files/flm02/bin/FLM02-1-4/openwrt-atheros-root.squ... ==OK
$ wget http://www.flukso.net/files/flm02/bin/FLM02-1-4/openwrt-atheros-vmlinux.... ==OK
$ sudo ./ap51-flash eth0 openwrt-atheros-root.squashfs openwrt-atheros-vmlinux.lzma ==Not OK

./ap51-flash: error while loading shared libraries: libpcap.so.0.8: cannot open shared object file: No such file or directory

What can i do to solve this ? Did i have to install libpcap.so.0.8 ?

Resurrecting v1.2

Hello
While clearing out the shed I found my ancient V1.2 Flukso. I got it connected, and the website reports a heartbeat and a 101 firmware.

What can be done with a V1.2 nowdays?

Ideally I would like to use the pulse input to monitor water.

Replies to very old topics

Flukso server?? is sending replies and follow-ups to very old topics.
Something is happening on this site?
Hope its not a sign of failing :(

Chrome has tagged the site cerificate as being out of date...

Baz